RAM 3500 Chassis Cab Truck 2WD L6-6.7L DSL Turbo (2010)
Air Door Actuator / Motor: Service and Repair
Mode Door Actuator - Installation
INSTALLATION
NOTE: The heating-A/C system is equipped with two mode door actuators, one for the panel/floor-air door and one for the defrost-air door.
PANEL/FLOOR DOOR ACTUATOR
1. Install the panel/floor door actuator (1) onto the back of the HVAC housing (2). If necessary, rotate the actuator slightly to align the splines on the
actuator output shaft (3) with those on the panel/floor door actuator coupler (4).
2. Install the screws (1) that secure the panel/floor door actuator (2) to the HVAC housing (3). Tighten the screws to 1.1 Nm (10 in. lbs.).
3. Connect the HVAC wire harness connector (4) to the panel/floor door actuator.
4. Install the instrument panel See: Body and Frame/Interior Moulding / Trim/Dashboard / Instrument Panel/Service and Repair/Instrument Panel -
Installation.
5. Reconnect the negative battery cable.
6. Initiate the Actuator Calibration function using a scan tool See: Testing and Inspection/Component Tests and General Diagnostics/HVAC System
Test.
DEFROST DOOR ACTUATOR