Page 5
background image

Tighten the screws to 10 Nm (90 in. lbs.).

6. Do not reconnect the battery negative cable at this time. The Supplemental Restraint System (SRS) verification test procedure should be performed

following service of any SRS component. See: Service and Repair.

Passenger Air Bag - Removal

REMOVAL

WARNING: To avoid serious or fatal injury on vehicles equipped with airbags, disable the Supplemental Restraint System (SRS) before

attempting any steering wheel, steering column, airbag, seat belt tensioner, impact sensor, or instrument panel component
diagnosis or service. Disconnect and isolate the battery negative (ground) cable, then wait two minutes for the system capacitor to
discharge before performing further diagnosis or service. This is the only sure way to disable the SRS. Failure to take the proper
precautions could result in accidental airbag deployment.

WARNING: To avoid serious or fatal injury when removing a deployed airbag, rubber gloves, eye protection, and a long-sleeved shirt should

be worn. There may be deposits on the airbag unit and other interior surfaces. In large doses, these deposits may cause irritation
to the skin and eyes.

NOTE: The following procedure is for replacement of an ineffective or damaged passenger airbag. If the airbag is ineffective or damaged, but

not deployed, review the recommended procedures for handling non-deployed supplemental restraints. See: Service and Repair . If the
passenger airbag has been deployed, review the recommended procedures for service after a supplemental restraint deployment
before removing the airbag from the vehicle. 
See: Service and Repair .

1. Disconnect and isolate the battery negative cable. Wait two minutes for the system capacitor to discharge before further service.
2. Remove the top cover from the top of the instrument panel. See: Body and Frame/Interior Moulding / Trim/Dashboard / Instrument Panel/Service

and Repair/Instrument Panel Cover - Removal.

3. Remove the glove box from the instrument panel. See: Body and Frame/Interior Moulding / Trim/Glove Compartment/Service and

Repair/Instrument Panel Glove Box - Removal.

4. Reach up into the instrument panel between the upper glove box opening reinforcement and the cross car beam (4) to access and disconnect the

instrument panel wire harness connector (2) from the airbag inflator pigtail wire connector on the right side of the instrument panel airbag support
bracket. To disconnect the connector:
a. Slide the red Connector Position Assurance (CPA) lock on the top of the connector toward the side of the connector.
b. Depress the connector latch tab and pull the two halves of the connector straight away from each other.

5. Remove the two screws (3) that secure the passenger airbag lower bracket to the instrument panel airbag support bracket.