dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Keyless Entry Module|Removal|Page 40 > < Keyless Entry Module|Removal|Page 38
Page 1
background image

Keyless Entry Module: Service and Repair
Installation

INSTALLATION

WARNING:  To avoid serious or fatal injury on vehicles equipped with airbags, disable the supplemental restraint system before attempting
any steering wheel, steering column, airbag, seat belt tensioner, impact sensor, or instrument panel component diagnosis or service. Disconnect
and isolate the battery negative (ground) cable, then wait two minutes for the system capacitor to discharge before performing further
diagnosis or service. This is the only sure way to disable the supplemental restraint system. Failure to take the proper precautions could result
in accidental airbag deployment.

1. Position the Sentry Key REmote Entry Module (SKREEM) (1) onto the steering column (2) with the antenna ring oriented around the ignition lock

cylinder housing.

2. Install and tighten the screw (3) that secures the SKREEM to the steering column housing. Tighten the screw to 2 Nm (20 in. lbs.).

3. Reconnect the wire harness connector (2) to the SKREEM (1).

Keyless Entry Module|Removal|Page 40 > < Keyless Entry Module|Removal|Page 38