Removal
REMOVAL
1. Remove the torque converter.
2. Remove the torque converter hub seal with suitable screw and slide hammer.
Installation
INSTALLATION
1. Position the torque converter hub seal (1) over the input shaft and against the transmission oil pump.
2. Using Seal Installer 8902A (2), install a new torque converter hub seal.
3. Install the torque converter.