dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Radiator Cooling Fan Motor Relay > < Radiator Cooling Fan Control Module|Locations
Page 1
background image

Radiator Cooling Fan Control Module: Testing and Inspection

FAN CONTROLLER CHECK 

1. Remove condenser fan motor connector.
2. Start the engine and run it at idle.
3. Turn the A/C switch to ON and maintain the coolant temperature at 80 °C (176 °F) or less.

4. When measuring the voltage between the fan control module-side connector terminals, check that the value changes repeatedly as indicated by (1)

- (3) below. 
(1) 0 Volts 
(2) 8.2 ± 2.6 Volts
(3) Battery positive voltage ± 2.6 Volts 

5

If the voltage does not repeatedly change as indicated, replace the radiator fan motor and the fan control module assembly.

Radiator Cooling Fan Motor Relay > < Radiator Cooling Fan Control Module|Locations