Stratus Coupe V6-3.0L VIN H (2001)
3. Press the contact point of the male terminal down by holding a screwdriver [1.4 mm (0.06 inch) width] as shown in the figure. Lightly squeeze the
outer edge so the flats are parallel with the bottom.
INJECTOR CONNECTOR
1. Remove the waterproof cap.
2. Insert the tip of a screwdriver [1.4 mm (0.06 inch) width] into the connector as shown in the figure, press in the terminal lance, and pull out the
terminal.
CAUTION: Make sure the lance is pressed in before the terminal is inserted into the connector.
3. Press the contact point of the male terminal down by holding a screwdriver [1.4 mm (0.06 inch) width] as shown in the figure.
How to Cope With Intermittent Malfunctions
Most intermittent malfunctions occur under certain conditions. If those conditions can be identified, the cause will be easier to find.
TO COPE WITH INTERMITTENT MALFUNCTION;
1. Ask the customer about the malfunction
Ask what it feels like, what it sounds like, etc. Then ask about driving conditions, weather, frequency of occurrence, and so on.
2. Determine the conditions from the customer's responses
Typically, almost all intermittent malfunctions occur from conditions like vibration, temperature and/or moisture change, poor connections. From
the customer's responses, it should be reasoned which condition is influenced.
3. Use simulation test
-
In the cases of vibration or poor connections, use the simulation tests below to attempt to duplicate the customer's complaint. Determine the