eagle Workshop Repair Guides

Eagle Workshop Service and Repair Manuals

Coolant Temperature Override Switch|Page 1051 > < Coolant Temperature Override Switch
Page 1
background image

Thermal Vacuum Valve: Description and Operation
High Temperature Vacuum Signal Modulator

Description

This unit is located at the rear of the engine compartment and is connected to the EGR vacuum signal hose. The modulator opens when the
underhood air temperature reaches 115° F and causes a weakened vacuum signal to the EGR valve. As a result, the amount of exhaust gas being
recirculated is decreased.

Coolant Temperature Override Switch|Page 1051 > < Coolant Temperature Override Switch