Blower Motor: Service and Repair

1. Disconnect coolant level switch electrical connector.
2. Remove coolant reservoir retaining strap and move reservoir aside.
3. Remove coolant reservoir mounting bracket bolts and the bracket.
4. Pry off retaining clip and disconnect wires from blower motor.
5. Remove blower motor mounting screws and the blower motor.
6. Reverse procedure to install.