Summit L4-1795cc 1.8L SOHC (1995)
Rectifier Diode / Bridge: Testing and Inspection
Diode Trio Test
Diode Trio Test
Check three diodes for continuity by connecting an ammeter to both ends of each diode. If there is no continuity in both directions, diode is faulty and
heatsink assembly must be replaced.