eagle Workshop Repair Guides

Eagle Workshop Service and Repair Manuals

Brake Proportioning/Combination Valve|Service and Repair > < With Antilock Brakes
Page 1
background image

Brake Proportioning/Combination Valve: Testing and Inspection
Without Antilock Brakes

FUNCTION TEST 

1. Connect two pressure gauges, one each to the input side and output side of the proportioning valve, as shown.
2. Air bleed the brake line and the pressure gauge.
3. While gradually depressing the brake pedal, make the following measurements and check to be sure that the measured values are within the

allowable range.

a. Output pressure begins to drop relative to input pressure (split point). 

Standard value:  2.21 - 2.70 MPa (320 - 391 psi) 

b. Check that the output fluid pressure is at the standard value when the input fluid pressure increases according to the table.

Standard value:                       
Input fluid pressure:  6.07 MPa (925 psi) 
Output fluid pressure:  3.19 - 3.68 MPa (462 - 533 psi) 

c. Output pressure difference between left and right brake lines. 

Limit: 0.4 MPa (57 psi) 

4. If the measured pressures are not within allowable ranges, replace the proportioning valve.

Brake Proportioning/Combination Valve|Service and Repair > < With Antilock Brakes