Vacuum Reservoir HVAC: Service and Repair

A/C Vacuum Reservoir Tank and Bracket 

Removal and Installation

1. Disconnect the rubber vacuum source hose from the A/C vacuum check valve.

2.

Disconnect the vacuum hose harness from the solenoid and from the water valve.

3.

Disconnect the vacuum hose harness from the inboard side of the A/C evaporator case and remove from under the wire harness retaining cap.

4.

Remove the two screws from the mounts and remove A/C vacuum reservoir tank and bracket.

For installation, follow removal steps in reverse order. Check system for proper operation.