ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Air Door, HVAC > < Accumulator HVAC|Service and Repair
Page 2
background image

5.

Loosen fitting connecting accumulator to evaporator core.

6.

Remove two accumulator/dryer mounting bands and the clamp around the inlet tube. Disconnect accumulator/dryer from evaporator outlet tube
and remove assembly from vehicle.

7.

Reverse procedure to install. Use new O-rings lubricated with refrigerant oil.

8.

Leak test, evacuate and charge system. Check system for proper operation. 

Air Door, HVAC > < Accumulator HVAC|Service and Repair