ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Recycled Engine Coolant - Service Tips|Page 1262 > < Recycled Engine Coolant - Service Tips
Page 2
background image

ASSOCIATED WITH THE RETAIL SALE OF CHEMICAL PRODUCTS.

CAUTION

THE REINHIBITOR CHEMICALS PROVIDED WITH THIS EQUIPMENT ARE NOT APPROPRIATE FOR USE ON MEDIUM/HEAVY
TRUCK APPLICATIONS.

WARNING

ROTUNDA PREMIUM COOLANT REINHIBITORS # 1 AND # 2 HAVE BEEN SPECIFICALLY FORMULATED TO WORK WITH
ROTUNDA COOLANT RECYCLER (181-00003).

USE OF ANY OTHER CHEMICAL ADDITIVES WITH THIS SYSTEM WILL VOID ALL WARRANTIES FOR THE EQUIPMENT AND FOR
THE FINAL COOLANT PRODUCT.

SERVICE PROCEDURE

DIRECTIONS FOR PROCESSING USED ENGINE
COOLANT WITH ROTUNDA COOLANT
RECYCLER

1.

Close the drain valve on the unit.

2.

Open the fill valve.

3.

Pour used engine coolant into the funnel on the side of the unit.

NOTE

MAXIMUM CAPACITY 15 25 GALLONS (95 L).

4.

Insert the outlet hoses of the recycler into clean, properly labeled containers. One (1) container is for the outlet process water and the other
container is for distilled ethylene glycol.

5.

Push the "ON" switch on the front to start the operation. The unit will process 1 gallon (3.8 L) per hour of operation and will automatically shut off
when cycle is complete.

6.

Add reinhibitor following the directions in this article.

7.

Open the drain valve to drain the residue from the distillation vessel. Dispose of residue in accordance with all local. state and federal regulations.

ADDING REINHIBITOR CHEMICALS

1.

Process the coolant according to the directions listed in this article

2.

Thoroughly mix 4 fl oz (118 ml) of Reinhibitor # 1 to each gallon of distilled ethylene glycol.

3.

Thoroughly mix 4 fl oz (118 ml) of Reinhibitor # 2 to each gallon of distilled ethylene glycol.

4.

Mix well.

5.

Check the pH level of the coolant. The pH level must be between 9 and 11.

6.

Add enough water to the concentrated coolant to produce a 50/50 mixture of coolant and water.

NOTE

THE CONCENTRATED COOLANT MUST BE MIXED WITH WATER TO MEET THE NECESSARY ENGINE FREEZE PROTECTION.

7.

Check the coolant freeze point of the 50% coolant solution. Freeze point should be -34°F (-37°C).

Consult the Rotunda Coolant Recycler Manual for more detailed operating instructions. Call 1-800-ROTUNDA, 8 AM to 8 PM EST, for inquiries
regarding the Rotunda Coolant Recycler and to order the Reinhibitor (187-R0001).

PART NUMBER

PART NAME

Rotunda # 187-R0001

Rotunda Premium Coolant Reinhibitor

WARRANTY CLAIMS: Dealer can claim recycled engine coolant by Ford approved process via a warranty repair on an 1863 claim as follows:

Part Number: RECCOOL (not a valid part number, but it is recognized on an 1863 claim).

Recycled Engine Coolant - Service Tips|Page 1262 > < Recycled Engine Coolant - Service Tips