ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Ported Vacuum Valves|Page 1996 > < Vacuum Delay Valve, EVAP|Description and Operation
Page 1
background image

Vacuum Delay Valve: Testing and Inspection
Ported Vacuum Valves

Fig. 22 Ported vacuum switches & vacuum control valves

1.

With engine cold, ensure that passage A to B is closed, and passage A to C is open, Fig. 22.

2.

Start engine and run until it reaches normal operating temperature, then ensure that passage A to B is open and passage A to C is closed. On
4-port valve, check A1 to B1 and A2 to B2 separately.

3.

If valve does not operate as described, replace valve.

Ported Vacuum Valves|Page 1996 > < Vacuum Delay Valve, EVAP|Description and Operation