ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Rectifier Diode / Bridge, Alternator > < Diagram Information and Instructions|Page 3385
Page 1
background image

Diode Trio: Testing and Inspection

Fig. 9 Regulator plug. Jumper wire connection

Test Procedure

1.

Disconnect electric choke, if equipped.

2.

Disconnect voltage regulator wiring connector.

3.

Connect a jumper wire between the ``A'' and ``F'' terminals of the voltage regulator wiring connector, Fig. 9.

4.

Connect voltmeter to battery clamps. Then, start and idle engine.

5.

Observe and note voltmeter reading.

6.

Move the voltmeter positive lead to the alternator ``S'' terminal and note voltage reading.

Test Results

1.

If voltmeter reading is within {1/2} of battery voltage, the diodes are satisfactory.

2.

If voltmeter reading is approximately 1.5 volts, the alternator has a shorted negative diode or a grounded stator winding.

3.

If voltmeter reading is approximately 1.5 volts less than battery voltage, the alternator has a shorted positive diode.

4.

If voltage reading is approximately 1 to 1.5 volts less than {1/2} battery voltage, the alternator has an open positive diode.

5.

If voltage reading is 1 to 1.5 volts above {1/2} battery voltage, the alternator has an open negative diode.

6.

Reconnect electric choke into circuit after tests are completed, if equipped.

Rectifier Diode / Bridge, Alternator > < Diagram Information and Instructions|Page 3385