ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

303-03C Engine Cooling - 1.8L Duratec-HE (MI4)-2.0L Duratec-HE (MI4) > < Coolant Outlet Connector
Engine Cooling - 1.6L Duratec-16V Ti-VCT (Sigma) - Coolant Shutoff Valve C-MAX 2003.75 (06/2003-)
Removal and Installation

Special Tool(s)

Remover/Installer, Coolant Hose Clamp

303-397

  1. Drain the cooling system.
    For additional information, refer to: Cooling System Draining, Filling and Bleeding (303-03B Engine Cooling - 1.6L Duratec-16V Ti-VCT (Sigma), General Procedures).
  1. Lower the vehicle.
  1. Remove the throttle body.
    For additional information, refer to: Throttle Body (303-04B Fuel Charging and Controls - 1.6L Duratec-16V Ti-VCT (Sigma), Removal and Installation).

4. Remove the components in the order indicated in the following illustration(s) and table(s).

 
Item
Part Number
Description
2
-
Coolant shutoff valve electrical connector
3
-
Coolant shutoff valve
4
-
Coolant shutoff valve O-ring seal

5. To install, reverse the removal procedure.

Removal Details

Item 1 : Coolant shutoff valve to thermostat housing coolant hose

  1. Using the special tool, disconnect the coolant shutoff valve to thermostat housing coolant hose.

303-03C Engine Cooling - 1.8L Duratec-HE (MI4)-2.0L Duratec-HE (MI4) > < Coolant Outlet Connector