Safety Recall - CNG Backfire and Tank Valve Concern|Page 4512 > < Safety Recall - CNG Backfire and Tank Valve Concern|Page 4510
Page 69
background image

5.

Transfer outlet fitting from old tank valve to tank valve on replacement fuel tank. Tighten to 23 Nm (17 lb/ft). Refer to Figure 16.

6.

Lubricate O-ring with clean engine oil, then install new check valve. Tighten to 23 Nm (17 lb/ft). See Figure 16.

7.

Install PRD line to PRD. Tighten to 23 Nm (17 lb/ft). Position line as shown in Figure 17.