Contour L4-122 2.0L CNG DOHC VIN Z SFI (1996)
4.
Remove retaining nuts from intake air resonator assembly, then unsnap MAF sensor retainers from air cleaner cover. See Figure 22.
5.
Disconnect MAF sensor from air cleaner cover.
6.
Slightly raise intake air resonator assembly, then disconnect Intake Air Temperature (IAT) sensor electrical connector from bottom of air cleaner
outlet tube.
7.
Remove intake air resonator assembly and compuvalve outlet line from vehicle.