The heater blower motor switch resistor has the following features:
-
The assembly is located in the engine compartment on the evaporator housing toward the center of the vehicle.
-
Three resistor elements are mounted on the resistor board to provide four blower motor speeds.
-
Depending on the heater blower motor switch position, series resistance is added or bypassed in the A/C blower motor circuit to decrease or
increase A/C blower motor speed.
-
An overheating protective device (thermal limiter) will open the resistor coil when the temperature reaches 121°C (250°F). interrupting the blower
motor operation in all speeds except HI.
-