Crown Victoria V8-4.6L Flex Fuel (2008)
Brake Lamp: Initial Inspection and Diagnostic Overview
Inspection and Verification
INSPECTION AND VERIFICATION
WARNING: If equipped with fire suppression system, refer to Fire Suppression System for Important Safety Warnings. Failure to follow this
instruction may result in serious personal injury.
1. Verify the customer concern.
2. Visually inspect for obvious signs of mechanical or electrical damage.
Visual Inspection Chart
3. If an obvious cause for an observed or reported concern is found, correct the cause (if possible) before proceeding to the next step.
4. If the concern is not visually evident, verify the symptom. GO to Symptom Chart. See: Symptom Related Diagnostic Procedures
Principles of Operation
PRINCIPLES OF OPERATION
NOTE: The stoplamps are powered directly from the stoplamp switch, not from the lighting control module (LCM).
The stoplamps are supplied voltage from the stoplamp switch. When the brake pedal is applied, the internal switch closes and voltage is supplied directly
to the high mounted stoplamp and the multifunction switch, which then routes the voltage to the rear stoplamps.