H3-H4

Test I: Intermittent No High Speed Controller Area Network (HS-CAN) Communication, One or
More Modules Are Not Respond

PINPOINT TEST I: INTERMITTENT NO HIGH SPEED CONTROLLER AREA NETWORK (HS-CAN) COMMUNICATION, ONE OR
MORE MODULES ARE NOT RESPONDING DURING NETWORK TEST

Normal Operation

An open circuit VDB04 (WH/BU) (HS-CAN +) or VDB05 (WH) (HS-CAN -) may cause intermittent or unreliable communication to all modules on
the HS-CAN. The HS-CAN network is used for communication between the following modules:
-

ABS module

-

Instrument cluster

-

Fire suppression module (police only, if equipped)

-

PCM

-

Vehicle dynamics module (VDM)

In the event that one of the 2 network circuits (HS-CAN + or HS-CAN -) becomes open to a module on the network, unreliable network