Crown Victoria V8-4.6L SOHC VIN 6 (1996)
5. Remove wiring from ash receptacle bracket. Reach in with a flat-blade screwdriver and lift up on the two spring stops to release the instrument
panel ash receptacle from the ash receptacle retainer.
6. Remove cigar lighter knob and element from instrument panel ash receptacle.
INSTALLATION
1. Install cigar lighter knob and element into instrument panel ash receptacle. Install instrument panel ash receptacle into ash receptacle bracket and
connect wiring harness.
2. Position the ash receptacle clips retainer to the instrument panel and slide rearward to engage retaining clips. Install the two retaining screws.
Tighten the screws to 2-3 N.m (18-26 Lb-In).
3. Connect wiring.