Crown Victoria V8-4.6L SOHC VIN 6 (1996)
PCV Valve Hose: Service and Repair
Crankcase Ventilation Hose
PCV Valve And Related Components
1. Remove air cleaner outlet tube.
2. Disconnect crankcase vent connector and hose from positive crankcase ventilation valve.
3. Disconnect crankcase vent connector and hose from throttle body adapter and vacuum fitting.
4. To install, reverse removal procedure.