ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Restraints - Control Module DTCs & Associated Fault PIDs|Page 7110 > < Restraints - Control Module DTCs & Associated Fault PIDs|Page 7108
Page 5
background image

Position the large RCM electrical connector into the RCM.

-

CAUTION:  Do not push the connector on to where the lever pivots and seats itself. Light pressure is needed to get the connector into
position on the RCM before using the lever to fully seat the connector.

With the large RCM electrical connector uniformly aligned to the RCM, lightly push in until a subtle audible click is heard and slight
resistance is felt.

5. NOTE:  The RCM has been removed for clarity.

Connect the large RCM electrical connector.
-

Using the connector position assurance lever, pivot it toward the RCM, drawing the connector into the RCM.
-

Make sure the thumb tab is engaged to the retainer on the RCM and is locked in place.

Vehicles with column shifter

6. Position the ashtray bracket, slide the retaining clips into place and install the screws.

Restraints - Control Module DTCs & Associated Fault PIDs|Page 7110 > < Restraints - Control Module DTCs & Associated Fault PIDs|Page 7108