ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Selector Lever - Column Shifter|Page 4809 > < Selector Lever - Column Shifter|Page 4807
Page 1
background image

Shifter A/T: Service and Repair
Selector Lever-Floor Shifter

Selector Lever - Floor Shifter 

Removal and Installation 

1. WARNING:  To avoid accidental deployment and possible personal injury, the backup power supply must be depleted before repairing

or replacing any front or side air bag supplemental restraint system (SRS) components and before servicing, replacing, adjusting or
striking components near the front or side air bag sensors, such as doors, instrument panel, console, door latches, strikers, seats and hood
latches.

The side air bag sensors are located at or near the base of the B-pillar.

To deplete the backup power supply energy, disconnect the battery ground cable and wait at least one minute. Be sure to disconnect
auxiliary batteries and power supplies (if equipped). 

Disconnect the battery ground cable. Wait at least one minute before proceeding with the procedure to allow the backup power supply to
deplete its energy.

2. Remove the instrument panel finish panel and disconnect the electrical connector.

3. Lift the console finish panel and remove.

4. Push shift handle bezel down and disconnect TCS harness.

Selector Lever - Column Shifter|Page 4809 > < Selector Lever - Column Shifter|Page 4807