ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Lifter / Lash Adjuster, Valve > < Camshafts|Page 1585
Page 3
background image

Camshaft Runout

Special Tool(s)

1. NOTE:  Camshaft journals must be within specifications before checking runout.

Use a Dial Indicator Gauge with Holding Fixture to measure the camshaft runout.
^

Rotate the camshaft and subtract the lowest indicator reading from the highest indicator reading.

^

If out of specification, install new components as necessary.

Lifter / Lash Adjuster, Valve > < Camshafts|Page 1585