ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

A/C - Heater Core Electrolysis/Leakage|Page 3507 > < A/C - Heater Core Electrolysis/Leakage|Page 3505
Page 2
background image

6. Remove the white coupling retainer from the tube.

7. Spread the retainer tabs apart and slide the retainer off the tube.
8. Discard the retainer.

CONNECT

1. Clean the tubes and lubricate with plain water.

2. Install a new coupling retainer, spacer, and lubricated O-ring seals into the quick disconnect coupling housing.

3. Push the heater water hose with a quick disconnect coupling onto the tube.
4. Make sure the coupling is fully engaged by lightly pulling on the heater water hose.

A/C - Heater Core Electrolysis/Leakage|Page 3507 > < A/C - Heater Core Electrolysis/Leakage|Page 3505