ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Condenser HVAC > < Compressor Fitting HVAC|Service Precautions|Page 7135
Page 2
background image

-

Discard the O-ring seal.

7. CAUTION:  Use a wrench on each side of the fitting to prevent damage to the A/C fitting.

Disconnect the compressor manifold and tube assembly from the condenser and remove the compressor manifold and tube assembly.
-

Discard the O-ring seal.

INSTALLATION

1. To install, reverse the removal procedure.

-

Install new O-ring seals lubricated in clean mineral oil.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.

2. Evacuate, leak test, and charge the refrigerant system.

Condenser HVAC > < Compressor Fitting HVAC|Service Precautions|Page 7135