ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Electronic Leak Detection|Page 2852 > < Refrigerant|Capacity Specifications|Page 2849
Page 1
background image

Refrigerant: Testing and Inspection
Electronic Leak Detection

ELECTRONIC LEAK DETECTION

H10PM Refrigerant Leak Detector With Battery

SPECIAL TOOL(S)

CAUTION:  Good ventilation is necessary in the area where electronic A/C leak testing is to be carried out. If the surrounding air is
contaminated with refrigerant gas, the leak detector will indicate this gas all the time. Odors from other chemicals such as antifreeze, diesel
fuel, disc brake cleaner, or other cleaning solvents can cause the same problem. Using a fan to ventilate the area to be tested before proceeding
with the leak detection procedure is helpful in removing small traces of contamination from the air, but the fan should be turned off during
actual testing.

1. NOTE:  The system pressure should be between 413-551 kPa (60-80 psi) at 24°C (75°F) with the engine off

Using a circular motion, leak test all fittings in the refrigerant system using the Refrigerant Leak Detector. Follow the instructions included with
the leak detector for handling and operation techniques.

2. If a leak is found, recover the refrigerant.

-

Repair the system.

-

Test the system for normal operation.

Electronic Leak Detection|Page 2852 > < Refrigerant|Capacity Specifications|Page 2849