Voltage Regulator: Service and Repair
VOLTAGE REGULATOR
Removal
1. Remove the generator.
2. Remove the generator brush and terminal holder and the voltage regulator.
1
Remove the screws.
2
Remove the generator brush and terminal holder and the voltage regulator.
3. Separate the generator brush and terminal holder from the voltage regulator.
1
Remove the screw cap.
2
Remove the screws.
3
Separate the generator brush and terminal holder from the voltage regulator.
Installation
1. Install the brush and terminal holder on the voltage regulator.
1
Position the brush and terminal holder on the voltage regulator.
2
Install the screws.
3
CAUTION: Make sure the screw cap is installed over test terminal A to prevent accidental shorting of the battery positive (B+)
connection.
Install the screw cap.