15. Disconnect the vacuum harness connector.

16. Disconnect the crankcase vent tube quick connect coupling from the LH valve cover. For additional information, refer to Fuel Delivery and Air

Induction.

17. Disconnect the exhaust gas recirculation (EGR) system module electrical connector.
18. Disconnect the EGR system module vacuum hose connector.
19. Disconnect the upper and lower fittings and remove the exhaust manifold-to-EGR system module tube.
20. Remove the 2 bolts and the EGR system module.

^

Discard the EGR system module gasket.

21. Disconnect the fuel pressure and temperature sensor electrical connector.
22. Disconnect the evaporative emissions (EVAP) system vapor tube quick connect coupling from the intake manifold. For additional information,

refer to Fuel Delivery and Air Induction.

23. Disconnect the PCV coolant hose from the TB adapter.
24. Disconnect the vacuum harness connector from the intake manifold.
25. Disconnect the 8 fuel injector electrical connectors.
26. Disconnect the wiring harness retainer from the rear of the RH cylinder head.

27. Disconnect the coolant hose from the heater outlet tube.