E 250 V8-4.6L VIN W (2006)
Positive Crankcase Ventilation Valve: Service and Repair
POSITIVE CRANKCASE VENTILATION (PCV) VALVE
Removal and Installation
1. Disconnect the battery ground cable.
2. Remove the engine cover.
3. Disconnect the positive crankcase ventilation (PCV) valve electrical connector.
4. Disconnect the PCV valve tube quick-connect fitting and position the PCV tube aside.
5. Rotate the PCV valve counterclockwise and remove the PCV valve.
6. To install, reverse the removal procedure.