background image

Position the EPC solenoid bracket and loosely install the bolt.

4. NOTE:  The main control valve body bolts will be tightened in later steps.

Loosely install the main control valve body bolts.

5. Install the manual control valve detent lever spring and loosely install the bolt.

6. Tighten the main control valve body and cover plate bolts in the sequence shown.

^

Tighten to 10 Nm (89 inch lbs.).