E 250 Van V8-302 5.0L (1983)
Fig. 2 Positioning Pump In C-Clamp
Fig. 2 Positioning Pump In C-Clamp
1.
Remove pulley from pump.
2.
Remove outlet fitting, flow control valve and flow control valve spring from pump, then remove reservoir, Fig. 1.
3.
Place a suitable C-clamp in a vise.
4.
Position lower support plate T78P-3733-A2 over pump rotor shaft.
5.
Install upper compressor plate T78P-3733-A1 into upper portion of C-clamp.
6.
While holding compressor tool, place pump assembly into C-clamp with rotor shaft facing downward, Fig. 2.
7.
Tighten C-clamp until a slight bottoming of valve cover is observed.
8.
Through small hole located on side of pump housing, insert a suitable drift and push inward on valve cover snap ring. While pushing inward on
snap ring, place a screwdriver under snap ring edge and remove ring from housing, Fig. 3.
9.
Loosen C-clamp and remove upper compressor plate T78P-3733-A2, then remove pump assembly.
10.
Remove pump valve cover and O-ring.
11.
Remove rotor shaft, upper plate, cam and rotor assembly and two dowel pins.
12.
Remove lower plate and spring, by tapping housing on a flat surface.
13.