E 250 Van V8-7.3L DSL Turbo VIN F (1995)
1. Pull the wiring harness connector from the sensor.
2. Remove the sensor hold down bolt and remove the sensor from the axle housing.
INSTALLATION
1. Clean the axle mounting surface. Use care to prevent dirt from entering the axle housing.
2. Inspect and clean the magnetized sensor pole piece to make sure that it is free from loose metal particles which could cause erratic system
operation. Replace the sensor O-ring.
3. Lightly lubricate the sensor O-ring with motor oil, align the sensor bolt hole, and install. Do not apply force to the plastic sensor connector. The
sensor flange should slide to the mounting surface. This will make sure the air gap setting is between 0.127-1.14mm (0.005-0.045 in).
4. Install the hold down bolt and tighten to 34-40 Nm (25-30 ft lb).
5. Push the electrical connector on the sensor.