VOLTAGE REGULATOR
Removal
1. Remove the generator.
2. Remove the 4 generator brush and terminal holder - voltage regulator screws and position the generator brush and terminal holder - voltage
regulator aside.
3. Remove the test terminal A screw cap, the 2 generator brush and terminal holder screws and separate the generator brush and terminal holder from
the generator voltage regulator.
Installation