Vacuum Reservoir HVAC: Service and Repair

VACUUM RESERVOIR

Removal and Installation

1. Remove the evaporator core housing.

2. Remove the vacuum reservoir tank.

1

Remove the screw.

2

Drill out the heat stake.
-

Remove the vacuum reservoir tank.

3. Disconnect the vacuum harness.

4. NOTE:  Use a screw in place of the heat stake to install the vacuum reservoir.

To install, reverse the removal procedure.