E 350 V8-6.0L DSL Turbo (2007)
Fuel Injector Control Module: Service and Repair
FUEL INJECTOR CONTROL MODULE
Removal and Installation
1. Retrieve the module configuration. Carry out the module configuration retrieval steps of the Programmable Module Installation (PMI) procedure.
2. Turn the ignition switch to the OFF position.
3. Remove the 3 bolts and position the degas bottle aside. To install, tighten to 10 Nm (89 lb-in).
4. NOTICE: Make sure both latches are released before removing the electrical connectors or connector damage can occur.
Disconnect the fuel injector control module (FICM) electrical connectors. Position the wiring harness aside.
5. Disconnect the bulkhead connector and position aside.
-
To install, tighten to 5 Nm (44 lb-in).
6. Remove the 4 bolts and the FICM.
-
To install, tighten to 13 Nm (10 lb-ft).