ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Procedures|Page 5557 > < Procedures|Page 5555
Page 6
background image

1

Connect the pressure line to the radiator in-tank fluid cooler.

2

Connect the return line to the other side of the radiator in-tank fluid cooler.

3

Place the outlet end of the return line in the fluid tank reservoir.

15. NOTE:  Cycling the pump on and off will help dislodge contaminants in the cooler system.

Switch the pump ON. Allow the fluid to circulate a minimum of 5 minutes. 

16. Switch the pump OFF.
17. Disconnect the cleaner pressure line at the fluid cooler tube.
18. Using compressed air, blow through the fluid cooler inlet tube until all fluid is removed.
19. Remove the rubber hoses from fluid cooler tubes.
20. If equipped, flush the remote filter manifold and make sure that the small bypass orifice is free of foreign material.
21. Flush the remote filter housing and clean the magnet (if equipped).

22. NOTE:  Install a new oil-to-air (OTA) cooler as part of a transmission overhaul, or when installing a remanufactured transmission.

Backflush and forward flush the OTA.

23. Backflush and forward flush the radiator in-tank cooler.
24. Install a new remote filter element (if equipped).
25. Carry out the transmission fluid cooler flow test. See: Testing and Inspection/Component Tests and General Diagnostics/Torqshift Automatic

Transmission/Transmission Fluid Cooler Flow Test