Condenser HVAC: Service and Repair

CONDENSER CORE

REMOVAL

CAUTION:  Refrigerant Compressor Oil (Mineral Oil) F73Z-19577-AA (Motorcraft YN-9-A) should be used to lubricate R-134a refrigerant
system O-ring seals only and should not be added to R-134a refrigerant systems as an A/C compressor lubricant. PAG Refrigerant Compressor
Oil F7AZ-19589-DA (Motorcraft YN-12-C) or equivalent meeting Ford specification WSH-M1C231-B only should be used as an A/C
compressor lubricant.

NOTE:  Installation of a new suction accumulator is not required when repairing the air conditioning system except when there is physical evidence of
system contamination from a failed A/C compressor or damage to the suction accumulator.
 

1. Recover the refrigerant.

2. Disconnect the condenser fittings.

-

Discard the O-ring seals.

3. Remove the cooling module.
4. Remove the condenser bracket nuts and the condenser.

INSTALLATION

1. To install, reverse the removal procedure.

-

Install new O-ring seals lubricated in clean mineral oil.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.

2. Evacuate, leak test and charge the refrigerant system.