ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Expansion Valve|Locations|Page 8546 > < Expansion Valve|Locations|Page 8544
Page 1
background image

Expansion Valve: Service and Repair

REMOVAL

1. Remove the A/C evaporator core. See: Evaporator Core/Service and Repair

2. Remove the thermocouple.

1. Remove the electrical wire wrap tape.
2. Remove the thermocouple.

3. Remove the A/C evaporator expansion valve.

1. Disconnect the refrigerant lines.

^

Disconnect the A/C liquid jumper line.

^

Disconnect the inlet line.

NOTE: Use a wrench on each side of the fitting to prevent damage to the A/C fitting.

2. Remove the A/C evaporator expansion valve.

INSTALLATION

1. Install the A/C evaporator expansion valve.

1. Install new green O-rings.

^

Lubricate with clean Motorcraft Refrigerant Oil YN-12b or equivalent meeting Ford specification WSH-M1C23-B.

NOTE: The green O-ring(s) cannot be seen. They are located in the connection(s).

2. Install the A/C evaporator expansion valve.
3. Connect the refrigerant lines.

^

Connect the A/C liquid jumper line.

Expansion Valve|Locations|Page 8546 > < Expansion Valve|Locations|Page 8544