Alternator Brush: Specifications
Operational Specifications (95/130 Amp Generator)

Slip Ring Turning 
Min. Diameter .....................................................................................................................................................................................  26.16 mm (1.03 Inch)
Max. Runout ....................................................................................................................................................................................  0.013 mm (0.0005 Inch)

Brush Length 
New ...................................................................................................................................................................................................  18.01 mm (0.709 Inch)
Wear Limit ............................................................................................................................................................................................  4.57 mm (0.18 Inch)