2. Mount the (A) torque converter on the (B) stator support so that the splines on the one-way clutch inner race engage the mating splines of the

stator support.

NOTE:  The assembled pump can be used for the following steps.

3. Hold the stator support stationary and rotate the torque converter counterclockwise.

-

The torque converter should rotate freely, with no signs of scraping.

-

If there are signs of scraping, replace the torque converter.

Stator to Turbine Interference Check

1. Position the torque converter with the pump drive up.

NOTE:  The stator support can remain in the pump assembly during this test.

2. Install the stator support, engaging the mating splines of the stator support shaft.

3. Install the input shaft, engaging the splines with the turbine hub.

Torque Converter|Flow of Diagnosis|Page 5630 > < Torque Converter|Flow of Diagnosis|Page 5628