Transmission Cooler: Service and Repair
Cooler Bypass Valve

1. Plug the CBV converter-out-to-cooler inlet with a 13 x 1.5 mm plug.

2. Place a 0.5-inch flat washer over the case converter-out fitting threads.

3. Connect the cleaner pressure line to the case converter-out fitting.

4. Place the CBV into the solvent tank.

CAUTION:  Make sure the CBV is in the solvent tank before switching on the solvent pump. Also make sure the CBV fitting is pointing
downward so the solvent does not spray up out of the tank.