ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Leak Detection Solenoid, Evaporative System > < Evaporative Emission Control Canister|Service and Repair|Page 3012
Page 4
background image

Van/wagon vehicles

6. Remove the heat shield bolt.

-

To install, tighten to 18 Nm (13 lb-ft).

7. Remove the lower EVAP canister and bracket assembly bolts and the heat shield.

-

To install, tighten to 18 Nm (13 lb-ft).

All vehicles

8. NOTE:  Van/wagon vehicle lower EVAP canister and bracket assembly bolts will already be removed.

Remove the EVAP canister and bracket assembly bolts.
-

To install, tighten to 18 Nm (13 lb-ft).

9. Disconnect the EVAP canister-to-hydrocarbon filter canister tube quick connect coupling from the EVAP canister.

10. Separate and remove the EVAP canister from the bracket.

11. NOTE:  Lubricate the O-ring seals with clean engine oil.

To install, reverse the removal procedure.
-

Carry out the evaporative emission system leak test.  See: Testing and Inspection

-

Carry out the evaporative emission repair verification drive cycle.

Leak Detection Solenoid, Evaporative System > < Evaporative Emission Control Canister|Service and Repair|Page 3012