ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 5849 > < Initial Inspection and Diagnostic Overview|Page 5847
Page 4
background image

-

For vehicles equipped with a class I trailer tow package, while applying the brake pedal, measure the voltage between the trailer tow C4098-2,
circuit CAT06 (YE), harness side and ground.

-

For vehicles equipped with a class II trailer tow package, while applying the brake pedal, measure the voltage between the trailer tow connector
LH stop/turn lamp voltage supply pin, circuit CAT06 (YE), component side and ground.

-

Is the voltage greater than 10 volts?

Yes

The vehicle is operating correctly. SEND the trailer to an authorized camper/trailer repair facility.

No

For vehicles equipped with a class I trailer tow package, GO to T4.

For vehicles equipped with a class II trailer tow package, GO to T3.

-------------------------------------------------
T3 CHECK FOR VOLTAGE TO THE TRAILER TOW CONNECTOR (7-PIN) (LH TURN)

 

-

Disconnect: Trailer Tow C4099.

-

While applying the brake pedal, measure the voltage between the trailer tow C4099-1, circuit CAT06 (YE), harness side and ground.

-

Is the voltage greater than 10 volts?

Yes

INSTALL a new trailer tow connector. TEST the system for normal operation.

No

GO to T4.

-------------------------------------------------
T4 CHECK THE LH TRAILER TOW TURN RELAY

 

-

Disconnect: LH Trailer Tow Stop/Turn Relay.

-

Substitute a known good relay.

-

For vehicles equipped with a class I trailer tow package, while applying the brake pedal, measure the voltage between the trailer tow C4098-2,
circuit CAT06 (YE), harness side and ground.

Initial Inspection and Diagnostic Overview|Page 5849 > < Initial Inspection and Diagnostic Overview|Page 5847