ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 5853 > < Initial Inspection and Diagnostic Overview|Page 5851
Page 8
background image

ground.

-

Is the voltage greater than 10 volts?

Yes

GO to T12.

No

REPAIR circuit CLS19 (VT/OG) for an open. TEST the system for normal operation.

-------------------------------------------------
T12 CHECK THE VOLTAGE SUPPLY CIRCUIT TO THE RH TRAILER TOW STOP/TURN RELAY FOR AN OPEN

 

-

Measure the voltage between the trailer tow RH stop/turn relay pin 3, circuit SBB48 (VT/RD), BJB face side and ground.

-

Is the voltage greater than 10 volts?

Yes

GO to T13.

No

REPAIR circuit SBB48 (VT/RD) for an open. TEST the system for normal operation.

-------------------------------------------------
T13 CHECK THE VOLTAGE SUPPLY CIRCUIT TO THE RH TRAILER TOW STOP/TURN RELAY USING THE RELAY GROUND
CIRCUIT PIN

 

-

Measure the voltage between the trailer tow RH stop/turn relay pin 3, circuit SBB48 (VT/RD), BJB face side and the trailer tow RH stop/turn
relay pin 2, circuit GD123 (BK/GY), BJB face side.

-

Is the voltage greater than 10 volts?

Yes

REPAIR circuit CAT09 (GN) for an open. TEST the system for normal operation.

No

REPAIR circuit GD123 (BK/GY) for an open. TEST the system for normal operation.

Initial Inspection and Diagnostic Overview|Page 5853 > < Initial Inspection and Diagnostic Overview|Page 5851