E 450 V8-5.4L (2009)
2. Remove the engine cooling fan and fan shroud.
3. Rotate the tensioner clockwise and remove the accessory drive belt from the crankshaft pulley.
4. NOTICE: This bolt is torque-to-yield and cannot be reused. Failure to follow these instructions may result in engine damage.
Using the Strap Wrench, remove the crankshaft pulley bolt and washer.
-
Discard the crankshaft pulley bolt.
5. Using the Crankshaft Vibration Damper Remover, remove the crankshaft pulley.
Installation
All engines
1. NOTE: If not secured within 4 minutes, the sealant must be removed and the sealing area cleaned with silicone gasket remover and metal surface
prep. Follow the directions on the packaging. Allow to dry until there is no sign of wetness, or 4 minutes, whichever is longer. Failure to follow
this procedure can cause future oil leakage.
Apply silicone gasket and sealant to the Woodruff key slot on the crankshaft pulley.
2. Lubricate the crankshaft pulley sealing area with clean engine oil prior to installation.