ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 6463 > < Initial Inspection and Diagnostic Overview|Page 6461
Page 5
background image

-

Ignition OFF.

-

Verify the ambient air temperature sensor is correctly installed and fully connected.

-

Is the ambient air temperature sensor correctly installed and fully connected?

Yes

GO to B2.

No

REINSTALL or RECONNECT the ambient air temperature sensor. TEST the system for normal operation.

-------------------------------------------------
B2 CHECK THE AMBIENT AIR TEMPERATURE SENSOR FUNCTION

 

-

Disconnect: Ambient Air Temperature Sensor C132.

-

Remove the ambient air temperature sensor.

-

Measure the resistance between the ambient air temperature sensor pins, component side, at an ambient temperature of 18-29.5°C (65-85°F).

-

Is the resistance between 8,000 and 14,000 ohms?

Yes

GO to B3.

No

INSTALL a new ambient air temperature sensor. TEST the system for normal operation.

-------------------------------------------------
B3 CHECK THE AMBIENT AIR TEMPERATURE SENSOR CIRCUIT FEED FOR AN OPEN

 

-

Disconnect: Overhead Console C930.

-

Measure the resistance between the overhead console C930-5, circuit VH407 (YE/GN), harness side and the ambient air temperature sensor
C132-1, circuit VH407 (YE/GN), harness side.

-

Is the resistance less than 5 ohms?

Yes

GO to B4.

No

REPAIR the circuit. TEST the system for normal operation.

-------------------------------------------------
B4 CHECK THE AMBIENT AIR TEMPERATURE SENSOR CIRCUIT RETURN FOR AN OPEN

Initial Inspection and Diagnostic Overview|Page 6463 > < Initial Inspection and Diagnostic Overview|Page 6461