ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 6776 > < Initial Inspection and Diagnostic Overview|Page 6774
Page 2
background image

-

Place the headlamp switch in the HEADLAMPS ON position and observe the headlamps.

-

Do the headlamps operate correctly?

Yes

GO to Z4.

No

REFER to Headlamps  See: Headlamp/Testing and Inspection.

-------------------------------------------------
Z4 CHECK THE IGNITION SWITCH INPUT

 

-

Place the headlamp switch in the OFF position.

-

Enter the following diagnostic mode on the scan tool: SJB DataLogger.

-

Monitor the SJB ignition switch PID (IGN_O_ECU, IGN_A_ECU, IGN_R_ECU, and IGN_S_ECU) while cycling the ignition switch through all
its positions.

-

Does the PID agree with the ignition switch positions?

Yes

GO to Z5.

No

REFER to Steering Column to diagnose the input from the ignition switch.  See: Steering and Suspension/Steering/Steering Column/Testing and
Inspection

-------------------------------------------------
Z5 CHECK THE TRANSMISSION GEAR INPUT

 

-

Ignition ON.

-

Enter the following diagnostic mode on the scan tool: PCM DataLogger.

-

Monitor the PCM transmission gear status PID (TR) while placing the gear selector lever through all its positions.

-

Does the PID agree with the gear selection?

Yes

GO to Z6.

No

REFER to Transmission Control Systems to diagnose the digital Transmission Range (TR) sensor input.  See: Powertrain Management/Transmission
Control Systems/Testing and Inspection

-------------------------------------------------
Z6 CHECK THE SJB FOR DRL CONFIGURATION

 

-

Enter the following diagnostic mode on the scan tool: SJB Configuration.

-

Check the SJB configuration and make sure the DRL feature is enabled.

-

Is the SJB DRL configuration enabled?

Yes

INSTALL a new SJB. TEST the system for normal operation.

No